Search
  • Home
  • Equipment
    Concrete series

    CONCRETE SERIES

    Concrete multi-functional nondestructive testerConcrete strength tester Nonmetal ultrasonic detector Impact echo audio detector
    Prestressed series

    Prestressed series

    Multi function detector of prestressed concrete beam Quality detector for grouting density of duct Back pull effective prestress detector Prestressed anchor cable (pole) tension detector
    Pile pole series

    Pile pole series

    Low strain detector for foundation pile Foundation pile acoustic transmission detector Steel guardrail column buried depth shock elastic wave detector Bolt quality detector
    Assembled series

    Assembled series

    Assembled structure multi-function detector
    Series of geotechnical materials

    Series of geotechnical materials

    Falling ball type resilient modulus tester Falling ball tester for geotechnical mechanical properties Cross hole rock mass mechanical property detector Geotechnical acoustic wave tester
    Railway special series

    Railway special series

    Railway concrete structure scanner Multi function nondestructive testing instrument for ballastless track (type III) Knock type tunnel lining defect detector
    Fast inspection series (mobile platform)

    Fast inspection series (mobile platform)

    Knock type tunnel lining defect detector Knock type concrete filled steel tube void detector Knock type building decoration void detector Percussion fastener loosening inspection instrument
    Monitoring equipment series

    Monitoring equipment series

    Network multi-function monitoring and testing instrument
  • System
  • Service
  • New Product
  • Support
    Technical Q & A Technical solutions University programs Standard specification Case Video
  • ShengTuo
    About Us News Course Leader Qualification Investor
  • Contact
  • Link:

  • Chengdu Headquarters:028-68611510 / 028-68611516

    Fax:028-68611530

  • Address: Chengdu City, Sichuan Province, Wuhou District City, province, Wu Xing 28 Road, west 4, 7, five,

    E-mail: 2931371275@qq.com

  • 关注服务号

  • ©2019 Sichuan Central Inspection Technology Inc. All Rights Reserved.

    尊敬的客户:
          由于运营商电话线路故障,9月27日-10月27日,公司部分电话暂时无法使用,目前正在进行全力抢修,由此造成的不便深表歉意。

    为方便业务往来可直接拨打: 

    130-0811-2958

    How does the software part improve the accuracy of the test?

    Classification:
    TECHNOLOGY SOLUTION
    Release time:
    2018/07/23
    Page view
    The accuracy of the buried depth of the column depends largely on the accuracy of the extraction of the reflected signal at the bottom of the column. In order to improve the extraction ability and accuracy, in addition to the spectrum analysis technology (FFT, MEM) for analyzing the test signals in EDMA, we have also developed Signal Matching to process the signals.
     
    Due to the similarity between the reflected signal and the incident signal, we introduce the "Fitting Matching" technology in the communication engineering into the system, and analyze the correlation with the incident signal (oscillation signal) to automatically The reflected signal is extracted and the initial moment of the reflected signal is automatically determined.
     
    In order to further improve the signal-to-noise ratio (S/N) and the accuracy and objectivity of the test results, and to avoid human error, we have also developed half-wave mobile technology and intelligent analysis functions in EDMA.
     
    Move the excitation position based on the reflected waveform. If the moving distance (time axis) is exactly 1/2 of the excitation excellent period, the free vibration portion of the excitation signal after the two waveforms are superimposed can be largely eliminated.
     
    Intelligent analysis functions mainly include:
     
    (1) From the multiple test results, use mathematical statistics to give the optimal test results;
     
    (2) According to different predicted column lengths, select the most suitable analytical method;
     
    (3) In order to prevent obvious misjudgment situations in the automatic resolution process, multiple check functions are available in the system.
     
    At the same time of testing, the degree of dispersion of various methods can be automatically determined. When the degree of dispersion is large, a warning prompt is automatically given. Provide objective judgments for on-site vibration and data selection.
    Useful
    (0)
    Useless
    (0)
    No content information display available
    Please add data record on website background.